<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" rel="stylesheet" href="../specs.xsl"?>

<specifications>
	<title>ULTRAFLUX XL SPRAY FLUXING SYSTEM SPECIFICATIONS</title>
	
	<section>
		<headLine>General Specifications</headLine>
		<sub>
			<label>Module Configuration:</label>
			<bodyLine>Compact, self-contained module consisting of liquid delivery system; power supplies; nozzle power generator; valves; electrical inputs and outputs; and controls and displays for liquid, compressed air and nozzle power.</bodyLine>
		</sub>
		<sub>
			<label>Dimensions:</label>
			<bodyLine>12&quot; W x 13&quot; D x 10&quot; H (300 X 250 mm)</bodyLine>
		</sub>
	</section>
	
	<section>
		<headLine>Wetted Materials</headLine>
		<sub>
			<label>Pump Systems:</label>
			<bodyLine>316 stainless steel; polyphenylene sulfide or graphite gears; Teflon&#174; PTFE seals; titanium spring; Buna-N, EDPM or Teflon&#174; valve seals and o-rings</bodyLine>
		</sub>
		<sub>
			<label>Pressure-reservoir Systems:</label>
			<bodyLine>316 stainless steel or high-density polyethylene reservoirs; borosilicate glass, 316 satinless steel, and Viton&#174; flowmeters and valves</bodyLine>
		</sub>
	</section>
	
	<section>
		<headLine>Standard Features</headLine>
		<sub>
			<label>Spray Module:</label>
			<bodyLine>Single ultrasonic nozzle mounted in a spray-shaping assembly</bodyLine>
		</sub>
		<sub>
			<label>Liquid Delivery Systems:</label>
			<bodyLine>Magnetically-coupled, positive displacement gear pump with electronically controllable flow rate; or, pressure-reservoir system that delivers liquid by applying air pressure to a closed vessel.</bodyLine>
		</sub>
		<sub>
			<label>Displays:</label>
			<bodyLine>Nozzle power: digital</bodyLine>
		</sub>
		<sub>
			<label />
			<bodyLine>Flow rate: digital (pump systems); variable-area flowmeter (pressure-reservoir systems)</bodyLine>
		</sub>
		<sub>
			<label />
			<bodyLine>Air pressure: analog gauge</bodyLine>
		</sub>
		<sub>
			<label>Flow Rate and Nozzle Power Adjustments:</label>
			<bodyLine>Front-panel mounted</bodyLine>
		</sub>
		<sub>
			<label>External Trigger Input:</label>
			<bodyLine>3 - 240 V AC or DC, switch or relay contact, N/O or N/C, for triggering spray on/off from an external source</bodyLine>
		</sub>
		<sub>
			<label>Alarm Output:</label>
			<bodyLine>Relay, N/O/ or N/C, attaches to user's external alarm device</bodyLine>
		</sub>
		<sub>
			<label>Error Input:</label>
			<bodyLine>Sounds alarm in the event of nozzle malfunction</bodyLine>
		</sub>
		<sub>
			<label>Flow Rate Calibration:</label>
			<bodyLine>Internal adjustment potentionmeter (pump systems only)</bodyLine>
		</sub>
		<sub>
			<label>Liquid Tubing:</label>
			<bodyLine>Teflon&#174; FEP, 1/4&quot; or 1/8&quot; OD</bodyLine>
		</sub>
		<sub>
			<label>Input Voltage Range:</label>
			<bodyLine>90 - 240 VAC</bodyLine>
		</sub>
	</section>
	
	<section>
		<headLine>Performance</headLine>
		<sub>
			<label>Spray Width Range:</label>
			<bodyLine>0.25" - 12" (6 - 300 mm) per module</bodyLine>
		</sub>
		<sub>
			<label>Flow Rate Range:</label>
			<bodyLine>0.016 - 3.4 gph (1 - 200 ml/min) per module</bodyLine>
		</sub>
		<sub>
			<label>Deposition Uniformity:</label>
			<bodyLine>&#177; 15%</bodyLine>
		</sub>
		<sub>
			<label>Median Drop Size Range:</label>
			<bodyLine>18 - 68 microns</bodyLine>
		</sub>
		<sub>
			<label />
			<bodyLine>PLC Control Custom turnkey systems available</bodyLine>
		</sub>
	</section>
</specifications>